(0° C ≤ TA ≤ 35° C)*
Unless otherwise specified, dynamic measurements are made with all outputs terminated into 50 Ω/VTT, where VTT = -2 V for ECL outputs and 0 V for TTL outputs.
td align="center" nowrap="nowrap">V td align="center" nowrap="nowrap">ns td align="center" nowrap="nowrap">
Symbol |
Parameter |
PRL-350LP |
Unit |
Min |
Typ |
Max |
RIN
|
Input Resistance |
49.5 |
50.0 |
50.5 |
Ω |
ROUT
|
Output Resistance |
49.5 |
50.0 |
50.5 |
Ω |
VTH+
|
Preset positive threshold voltage |
49.5 |
50.0 |
50.5 |
mV |
VTH-
|
Preset negative threshold voltage |
-50.5 |
-50.0 |
-49.5 |
mV |
VTH0
|
Preset zero threshold voltage(1)
|
-10 |
0 |
10 |
mV |
VOL
|
Output Low Level |
1.5 |
1.7 |
1.8 |
V |
VOH
|
Output High Level |
2.3 |
2.5 |
2.7 |
V |
IDC+
|
DC Input Current, +8.5 VDC |
|
175 |
200 |
mA |
IDC-
|
DC Input Current, -8.5 VDC |
|
-325 |
-350 |
mA |
VDC+
|
DC Input Voltage |
+7.5 |
+8.5 |
+12 |
V |
VDC-
|
DC Input Voltage |
-12 |
-8.5 |
-7.5 |
V |
VAC1
|
AC/DC Adapter Input Voltage, 120 VAC |
103 |
115 |
127 |
VAC2
|
AC/DC Adapter Input Voltage, 220 VAC |
206 |
230 |
254 |
tPLH
|
Propagation Delay to output↑ |
|
1.8 |
|
ns |
tPHL
|
Propagation Delay to output↓ |
|
1.8 |
|
tr/tf
|
Rise/Fall Times(2)
|
|
1100 |
1250 |
ps |
tSKEW
|
Skew between any 2 outputs |
|
750 |
1000 |
ps |
Vin I |
Minimum Input Voltage @ 150 MHz(3)
|
20 |
10 |
|
mVPP
|
Vin II |
Minimum Input Voltage @ 250 MHz(3)
|
20 |
10 |
|
mVPP
|
VCM
|
Input Common Mode Range |
-2.0 |
|
+3.0 |
V |
fmax
|
Max. Clock Frequency(4)
|
300 |
330 |
|
MHz |
|
Size |
1.3 x 2.9 x 3.9 |
in. |
|
Weight, w/o AC adapter |
7 |
Oz |
|
Shipping weight, w/AC adapter |
4 |
lb |
(1) If the switch is set to the center position (0 V threshold) a non-driven channel will oscillate and induce jitter in the driven channel. Connect any output to any input to stop the oscillation.
(2) 20%-80% for LVPECL. For the PRL-350LP, an unused complementary output must be either terminated into 50 Ω/VTT or AC coupled into a 50 Ω load; otherwise, output waveform distortion and rise time degradation will occur. Use the PRL-ACT-50 Dual Channel AC-Coupled 50 Ω Termination for terminating unused complementary outputs. Use the PRL-550LPQ4X, four channel LVPECL Terminator for the 50 Ω/VTT termination and for connection of LVPECL signals to 50 Ω input oscilloscopes. If preservation of DC levels is not required, then the PRL-SC-104A, 0.1 µf DC block or a 12 dB AC-coupled attenuator may be used to connect the LVPECL outputs to 50 Ω input instruments.
(3) In order to reduce jitter near fMAX, terminate the non-driven input into 50 Ω when the input voltage is less than 20 mVPP.