(0° C ≤ TA ≤ 35° C)*
Unless otherwise specified, dynamic measurements are made with all outputs terminated into 50 Ω.
Symbol |
Parameter |
PRL-350TTL |
Unit |
Min |
Typ |
Max |
RIN
|
Input Resistance |
49.5 |
50 |
50.5 |
Ω |
ROUT
|
Output Resistance |
49.5 |
50 |
50.5 |
Ω |
VTH+
|
Preset positive threshold voltage |
45 |
50 |
55 |
mV |
VTH-
|
Preset negative threshold voltage |
-55 |
-50 |
-45 |
mV |
VTH0
|
Preset zero threshold voltage(1)
|
-2 |
0 |
2 |
mV |
VOL
|
Output Low Level |
-0.5 |
0 |
0.5 |
V |
VOH
|
Output High Level |
2.0 |
2.2 |
2.4 |
V |
IDC1
|
DC Input Current, +8.5 V |
|
340 |
|
mA |
IDC2
|
DC Input Current, -8.5 V |
|
-440 |
|
mA |
VDC1
|
DC Input Voltage, +8.5 V |
7.5 |
8.5 |
12.0 |
V |
VDC2
|
DC Input Voltage, -8.5 V |
-12.0 |
-8.5 |
-7.5 |
V |
VAC1
|
AC/DC Adapter Input Voltage, 120 VAC |
103 |
115 |
127 |
V |
VAC2
|
AC/DC Adapter Input Voltage, 220 VAC |
206 |
230 |
254 |
V |
tPLH
|
Propagation Delay to output↑ |
|
2 |
|
ns |
tPHL
|
Propagation Delay to output↓ |
|
2 |
|
ns |
tr/tf
|
Rise/Fall Times, 10% - 90% |
|
350 |
|
ps |
tSKEW
|
Skew between any 2 outputs |
|
350 |
|
ps |
Vin I |
Minimum Input Voltage @ 150 MHz(2)
|
20 |
10 |
|
mVPP
|
Vin II |
Minimum Input Voltage @ 250 MHz(2)
|
40 |
20 |
|
mVPP
|
VCM
|
Input Common Mode Range |
-2.0 |
|
+3.0 |
V |
fmax
|
Max. Clock Frequency |
|
TBD |
|
MHz |
|
Size |
1.3 x 2.9 x 3.9 |
in. |
|
Weight, w/o AC adapter |
7 |
Oz |
|
Shipping weight, w/AC adapter |
3 |
lb |
(1) If the switch is set to the center position (0 V threshold) a non-driven channel will oscillate and induce jitter in the driven channel. Connect any output to any input to stop the oscillation.
For the PRL-350ATTL, very slight output waveform distortion and rise time degradation will occur when an unused complementary output is not terminated. For optimum performance, however, all outputs should be terminated.